Item(s) Added To Your Bag
Fluke 377 FC Non-Contact Voltage True-rms AC|DC Clamp Meter with iFlex
Fluke 377 FC Non-Contact Voltage True-rms AC|DC Clamp Meter with iFlex
The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.
Request Callback
Order In Bulk
Generate Quote
100% ORIGINAL Products
SECURE Payments
₹ 65,700.00
(GST inclusive price) i₹89,033.00
( - 26% OFF )
Description
The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.
Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.
Your job will get easier when you use the 377 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.
With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.
What's in the box?
|
General specifications | ||
General Maximum Voltage between any Terminal and Earth Ground | 1000 V | |
Battery | Type | 2 AA IEC LR6 alkaline |
Life | 200 hour | |
Display | Dual readout | |
Automatic Power Off | 20 minutes |
Electrical | ||||
AC Current: Jaw | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2 % ±5 digits (45 Hz to 66 Hz) | |||
Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 | |||
AC Current: Flexible Current Probe | ||||
Range | 2500 A | |||
Resolution | 1 A (≤2500 A) 0.1 A (≤999.9 A) | |||
Accuracy | 3 % ±5 digits (5 Hz to 500 Hz) | |||
Crest Factor (50/60Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. >2 | |||
Position Sensitivity | ||||
Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |
A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5 % | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0 % | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0 % | |
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
DC Current | ||||
Range | 999.9 A | |||
Resolution | 0.1 A | |||
Accuracy | 2 % ±5 digits1 | |||
[1]When using the ZERO function to compensate for offsets | ||||
AC Voltage: Field Sense | ||||
Range | 1000 V | |||
Resolution | 1 V (≤1000V) | |||
Accuracy | ≤4/0 AWG | 3 % ±5 digits (45 Hz to 66 Hz) | ||
≥4/0 AWG | 5 % ±5 digits (45 Hz to 66 Hz) | |||
Position wire as close as possible to jaw opening (see illustration). | ||||
AC Voltage: Test Leads | ||||
Range | 600.0 V 1000 V | |||
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) | |||
Accuracy | 1 % ±5 digits (20 Hz to 500 Hz) | |||
DC Voltage | ||||
Range | 600.0 V 1000 V | |||
Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) | |||
Accuracy | 1 % ±5 digits | |||
mV dc | ||||
Range | 500.0 mV | |||
Resolution | 0.1 mV | |||
Accuracy | 1 % ±5 digits | |||
Amps Frequency: Jaw | ||||
Range | 45 Hz to 66 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5 % ±5 digits | |||
Trigger Level | 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥ 5 A 100 Hz to 500 Hz, ≥ 10 A | |||
Amps Frequency: Flexible Current Probe | ||||
Range | 5.0 Hz to 500.0 Hz | |||
Resolution | 0.1 Hz | |||
Accuracy | 0.5 % ±5 digits | |||
Trigger Level | 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz,≥25 A | |||
Resistance | ||||
Range | 60.00 kΩ 6000 Ω 600.0 Ω | |||
Resolution | 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 10 Ω (≤60.00 kΩ) | |||
Accuracy | 1 % ±5 digits | |||
Capacitance | ||||
Range | 1000 μF | |||
Resolution | 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) | |||
Accuracy | 1 % ±4 digits | |||
Mechanical | ||||
Size (L x W x H) | 274 mm x 86 mm x 47 mm | |||
Weight (with Batteries) | 463 g | |||
Jaw Opening | 34 mm | |||
Flexible Current Probe Diameter | 7.5 mm | |||
Flexible Current Probe Cable Length (head to electronics connector) | 1.8 m | |||
Rogowski Coil Length | 450 mm | |||
Environmental | ||||
Operating Temperature | -10 °C to 50 °C | |||
Storage Temperature | -40 °C to 60 °C | |||
Operating Humidity (without condensation) | Non condensing (<10 °C) ≤90 % RH (10 °C to 30 °C) ≤75 % RH (30 °C to 40 °C) ≤45 % RH (40 °C to 50 °C) | |||
Temperature Coefficients | Add 0.1 x specified accuracy for each degree C >28 °C or <18 °C | |||
Ingress Protection | IEC 60529: IP30 (jaw closed) | |||
Operating Altitude | 2000 m | |||
Storage Altitude | 12 000 m | |||
Electromagnetic Compatibility (EMC) | ||||
International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2, CISPR 11: Group 1, Class B | |||
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | ||||
Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. | ||||
Korea (KCC) | Class A equipment (Industrial Broadcast & Communications Equipment) | |||
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | ||||
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |||
Safety | ||||
General | IEC 61010-1: Pollution degree 2 | |||
Measurement | IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V | |||
Current Clamp for Leakage Current Measurements | IEC 61557-13: Class 2, ≤30 A/m | |||
Wireless Radio | ||||
Radio Frequency Certification | FCC ID: T68-FBLE IC:6627A-FBLE | |||
Frequency Range | 2405 MHz to 2480 MHz | |||
Output Power | <100 mW | |||
Radio Frequency Data | Radio Frequency Data For Class A Devices SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf. |
Similar Products
More From Brands
Request Callback
We will get in touch with you
Enter your requirement details!
We will get in touch with you.